Good oxidation resistance in intermittent service to 870°C and in continuous service to 920°C
Continuous use of Alloy 304 in the 425-860°C range is not recommended if subsequent aqueous corrosion resistance is important
Alloy 304H has higher strength at elevated temperatures so is often used for structural and pressure-containing applications at temperatures above about 500°C and up to about 800°C
Alloy 304H will become sensitized in the temperature range of 425-860°C; this is not a problem for high temperature applications, but will result in reduced aqueous corrosion resistance.