Zhejiang Guanyu Stainless Steel Tube Co., Ltd  
  Directory | Useful Tool | Sitemap | Contact US | Home

         

Corrosion

Aluminium Corrosion Resistance for Plate-Fin Heat Exchanger





Aluminum cold plates and plate-fin heat exchanger are commonly used for liquid cooling in military and aerospace application because of their light weight and high performance. There are many factors to consider when designing these cold plates and heat exchangers: thermal performance, size, fluid pressure drop, weight, burst pressure, and corrosion resistance. This article will address the corrosion resistance considerations in designing, building, and operating aluminum cold plates and plate-fin heat exchanger.

Corrosion of Aluminum

Aluminum is known for its corrosion resistance. Under the right conditions, aluminum rapidly forms a protective oxide layer. Generally this occurs when oxygen is readily available and the surrounding medium has a moderate pH. There are two typical manifestations of aluminum corrosion: uniform corrosion and local corrosion. Uniform corrosion happens when the oxide layer is soluble in the corrosive medium.

"The oxide film is soluble in alkaline solutions and in strong acids…but is stable over a pH range of approximately 4.0 - 9.0."2 In uniform corrosion, the entire oxide layer is being stripped away faster than it can reform. Local corrosion, usually in the form of a pit, occurs when there is non-uniformity in the base metal or the surrounding environment. The metal may have a local concentration of alloying elements that creates a galvanic couple. Similarly, the surrounding environment may have a local concentration of active elements such as chlorides.

Cold plates and heat exchanger are used with many different fluids and typically involve the recirculation of the same fluid. One fluid that should not be used in aluminum cold plates and heat exchanger is water. Tap water, in particular, can contain active ions, such as copper, bicarbonates, chlorides, and/or other impurities that facilitate corrosion. Plus, over time, the recirculation of the same fluid in a closed loop will cause the dissolved oxygen to come out of solution. The resulting lack of oxygen will inhibit the formation of the oxide layer. Given enough time, aluminum will eventually corrode if isolated from oxygen and exposed to low quality water.

When water is the preferred choice for a heat transfer system, distilled water is usually combined with a glycol to reduce the freezing point and increase the boiling point. For the reasons stated above, it is critical that corrosion inhibitors be used. Corrosion inhibitors are controlled amounts of active ions (usually phosphates) that take over the role of oxygen in forming a corrosion resistant layer. Since these inhibitors depend on a chemical reaction with the aluminum, using low quality water such as tap water would reduce the inhibitors' effectiveness.

Designing for Corrosion Resistance

Alloy selection is a key factor in high corrosion resistance. For example, braze sheets, which separate the fluid passages in plate-fin heat exchangers, consist of an internal core and external clad layer that usually represents about 10% of the overall sheet thickness. The clad layer is a brazing alloy that joins the braze sheet to both the hot and cold fins and the braze sheet to the side bars. Vacuum brazing alloys use silicone and other elements to lower the melting point of the alloy. Since the braze alloy is more anodic than the core, the braze alloy provides cathodic protection, and thus corrosion protection. Cathodic protection is a concept that has been used in the ship building business for decades. For hulls made of steel, a plug made of an active element, like zinc, is used to protect the hull. Because zinc is more active than steel, the zinc corrodes faster that the steel. Among the alloying elements of aluminum, the alloys with a minimum of copper and iron have the best corrosion resistance.3 "3xxx series alloys are generally among those having the highest general corrosion resistance…The 6xxx alloys also have high resistance."

There are other considerations in cold plate and heat exchanger design. Internal fluid static pressure and external stresses put the core components under stress. These stresses often require that high strength alloys (6xxx series) be used for braze sheets and/or fins. Braze sheet thickness is a tradeoff between performance, weight, and corrosion protection. A thick braze sheet is heavy and reduces thermal performance. A thin braze sheet has less strength to withstand stresses and offers less corrosion protection. If a corrosive environment is present, thin braze sheets will withstand an attack for less time than a thicker sheet.

Cold Plate and Heat Exchanger Leak Testing

During their manufacturing process, cold plates and heat exchangers may be hydraulically tested with pure water. However, water should not remain in the unit longer than is needed to conduct the testing. A thorough drying process is critical to eliminate the possibility of water corrosion. "Bubble testing," or pressurizing a unit with a gas and submerging it in water, is used widely throughout the industry. This practice requires that the external surfaces be dried after testing.

Cold Plate and Heat Exchanger Operation

When operating a water/glycol cold plate or heat exchanger, it is important to have a maintenance plan. The typical maintenance activity is flushing and refilling the system with the proper mixture of inhibited ethylene glycol and water. This should be done on a periodic basis at an interval determined through system level testing during the operational evaluation phase. Periodically, the fluid pH and refractive index should be measured. These measurements will change over time. From these measurements, a flushing frequency could be determined.

During deployment, it is common for coolant systems to be "topped off". This practice should not harm the cold plate or heat exchanger as long as the glycol concentration is not diluted to the point of making the inhibitor ineffective. Inhibitor effectiveness is a function of top-off water quality, other metal types in the fluid loop, and the age of inhibitor in the system. If "topping off" is employed, it is advisable to monitor the pH of the fluid. If the pH falls below 4.0 or rises above 9.0, a system flush/fill should take place as soon as possible.

Corrosion resistance begins with the cold plate's or heat exchanger's design. By working with a manufacturer that understands corrosion and how to prevent it, you'll achieve a better product. It is also important to develop maintenance procedures that will maximize the life of the aluminum cold plate or heat exchanger.

1 Editor J.R. Davis, ASM Metals Handbook, Desk Edition, Volume 2, Materials Park, OH, 1998, page 501.



Related References:
  • U bend Stainless Steel Tube for Heat Exchanger
  • Heat Exchanger Tube
  • Specification/Standards for Heat Exchanger Tubes
  • Finned Tube and Pipe Heat Exchangers
  • Shell Tube and Pipe Heat Exchangers
  • Select Materials for Heat Exchanger Tubes with Substantial Pressure difference
  • The difference between Stainless Steel Tubing and Copper Tubing in Shell and Tube Heat Exchanger
  • Difference in Counter and Parallel Flow Heat Exchanger
  • Aluminum Corrosion Resistance for Cold Plates and Plate-Fin Heat Exchangers
  • Flow arrangement
  • Heat exchangers - Tubes and Pipes Standards
  • Selecting a Heat Exchanger Cooling Liquid
  • Selecting a Heat Exchanger Cooling Air
  • Selecting A Cold Plate Technology
  • Selecting a Cooling System: Ambient Cooling System | Recirculating Chiller | Liquid-to-Liquid Cooling System | Recirculating Chiller or Liquid-to-Liquid Cooling System
  • Selecting A Cold Plate Technology
  • Selecting A Pump
  • Selecting a Recirculating Chiller
  • Selecting A Modular Cooling System
  • Selecting an Liquid-to-Liquid Cooling System
  • How to Boost the Efficiency of Heat Exchanger
  • Comparison of Heat Exchanger Types
  • Parallel and Counter Flow Design
  • Direct contact heat exchanger

  • Types of heat exchangers
    Shell and tube heat exchanger
    Plate Heat Exchanger - Efficiency and Flexibility
    U Tube heat exchanger
    Regenerative heat exchanger
    Adiabatic wheel heat exchanger
    Plate fin heat exchanger
    Fluid heat exchangers
    Phase-change heat exchanger
    Parallel Flow Heat Exchanger
    Counter Flow Heat Exchanger
    Cross Flow Heat Exchanger
    Spiral heat exchangers
    Shell and Coil Heat Exchangers
    Brazed Heat Exchangers - Advantages | Applications | Specifications
    Titanium Heat Exchanger
    Plate and Shell Heat Exchanger - Applications | Specification
    Block Welded Heat Exchanger - Applications | Specification


    Heat Transfer | Forms | Effects | Conduction | Convection | Radiation | Heat Exchanger
    Metal Glossary | Metals Definitions | Heat Treatment of Metals | Passivation | Annealing | Quenching | Tempering | Heat Treatment of Steel | Heat Treating Definition | Heat Treating Stainless Steel | Technic of Metals Heat Treatment | Elements in Annealed State | Bright Anneaing | ASTM A380 | ASTM A967 | EN 2516 | 304 | 304L | 321 | 316L | 317L | 310S | 410 | 410S


  • Construction
  • Self cleaning
  • Applications
  • Selection
  • Pre Heater
  • Radiator
  • Air Conditioner Evaporator and Condenser
  • Large Steam System Condensers


  • TubingChina.com All Rights Reserved

    Directory | Standard | Heat | Heat Exchanger | Temperature | Pressure | Corrosion | Hardness | Surface | Properties | Select Stainless Steel | Contact US

    Useful Tools:

    Stainless Steel Weight Calculator
    Metals Weight Calculator
    Nickel Alloy Weight Calculator
    Copper Brass Alloy Weight Calculator
    Copper Brass Alloy Sheet Plate Weight Calculator
    Sheet Plate Weight Calculator
    Hardness Conversion Calculator
    Hardness Conversion Chart
    Rockwell Brinell Vickers Shore Hardness Conversion Chart
    Conversion Calculator
    Length Weight Temperature Volume Pressure Calculater
    Pipe Working Pressure Calculator
    Pressure Conversion Converter
    Round Bar Size Calculator
    Gauge Sizes
    Sheet Metal Gauge
    Pipe Schedule
    Nominal Pipe Size
    ANSI Pipe Chart
    Inch to mm Chart
    Stainless Steel Pipe Sizes
    Stainless Steel Tubing Sizes Chart
    Stainless Steel L H Grade
    Stainless Steel Density
    Conversion of Stainless Steel
    Nickel Alloy Grades Comparison Material Grade Chart Carbon Steel
    Structural Steel Comparison Chart



    Main Products:

    BA Tube | AP Tube
    Condenser Tubes Tubing
    Stainless Steel Reheater Tube Superheater Tubes
    Stainless Steel U bend Tube
    Nickel Alloy U bend Tubes
    Copper Alloy U Bend Tubes
    Heat Exchanger Tube
    Super Duplex Pipe
    Nickel Alloy Tube
    Brass Alloy Tubing
    Copper Nickel Alloys Tubes
    Stainless Steel Hollow Tube
    Stainless Steel Oval Tubing
    Stainless Steel Square Tubing
    Stainless Steel Rectangular Tubing
    Stainless Steel Capillary Tube
    Duplex Stainless Steel Pipe
    Seamless Stainless Steel Tubing
    Corrugated Stainless Steel Tubing
    Stainless Steel Twisted Tube
    Polishing Stainless Steel Tubing
    Stainless Steel Aircraft Tube
    Stainless Steel Hydraulic Tubing
    Stainless Steel Instrumentation Tubing
    Stainless Steel Angle Iron Bar
    Stainless Steel Mechanical Tube
    Bright Annealing Stainless Tube
    Heat resistant Stainless Steel
    Stainless Steel Welded Pipe
    Extruded Serrated Finned Tubes Integral Finned Tubes / Extruded Aluminum Finned Tubes
    Brass Alloys Copper Nickel Alloy Integral Low Finned Tubes
    HFW High Frequency Welded Helical Spiral Serrated Finned Tubes
    Corrosion Resistant Stainless Steel
    Corrosion Resistance Stainless Steel

    Stainless Steel Tubing Pipe

    304 Stainless Steel Pipe
    304L Stainless Steel Pipe
    304H Stainless Steel Pipe
    304/304L Stainless Steel Tubing
    309S Stainless Steel Pipe
    310S Stainless Steel Pipe
    316L Stainless Steel Tubing
    316Ti Stainless Steel Tube
    317L Stainless Steel Pipe
    321 321H Stainless Steel
    347 347H Stainless Steel
    904L N08094 Seamless Tubes
    17-4 PH 630 UNS S17400 Stainless Steel
    253MA S30815 Stainless Steel Tube
    S31254 254 SMO Pipe
    S31803 Stainless Steel
    2205 Duplex Pipe Tubing
    S32101 Stainless Steel
    S32304 Stainless Steel
    2507 Super Duplex Pipe
    S32750 Super Duplex Pipe
    S32760 Super Duplex Steel
    1.4462 Stainless Steel Pipe
    ASTM A213 | ASTM A269
    ASTM A312 | ASTM A511
    ASTM A789 | ASTM A790
    ASTM B161 / ASME SB 161 | ASTM B111
    EN 10216-5
    ASTM A789 ASME SA 789 S31803 S32205 S32101 S32750 S32760 S32304 S31500 S31260 Seamless Tubes
    EN 10216-5 1.4462 1.4362 1.4162 1.4410 1.4501 Seamless Tubes
    Nickel Alloy Tubing:

    UNS N08020 Nickel Alloy 20 Tubing
    UNS N02200 Nickel Alloy 200 Tube
    UNS N02201 Nickel Alloy 201 Pipe
    UNS N04400 400 Nickel Alloy Tubing
    N06600 600 2.4816 Nickel Alloy Pipe
    N06601 601 2.4851 Nickel Alloy Tubing
    N06625 625 2.4856 Nickel Alloy Tubes
    N08800 800 Nickel Alloy Tubes
    N08810 800H UNS N08810 Nickel Alloy Tubes
    N08811 800HT Nickel Alloy Tubes
    UNS N08825 825 2.4858 Nickel Alloy Seamless Pipes
    ASTM B622 N10276 Nickel Alloy Seamless Tubing
    ASTM B622 N06022 Hastelloy C-22 Nickel Alloy Tubes
    C28000 Brass Seamless Tubes C44300 Brass Seamless Tubes
    C68700 Brass Seamless Tubes
    C70600 Copper Nickel Tubes
    C71500 Copper Nickel Tubes
    DIN 2391 Seamless Precision Steel Tubes
    EN 10305-1 E215 E235 E355 Seamless Precision Steel Tube Tubing Tubes
    DIN 2393 St28 St34.2 St37.2 St44.2 St52.3 Welded Precision Steel Tubes
    EN 10305-2 E195 E235 E355 Welded Cold Drawn Precision Steel Tube